Betiatide

Brand Names: Kit For The Preparation Of Technetium Tc99m Mertiatide

Drug Class: General Prescription

Overview

DESCRIPTION Kit for the Preparation of Technetium Tc99m Mertiatide is used for the preparation of technetium Tc 99m mertiatide, a diagnostic radiopharmaceutical. It is supplied as a sterile, nonpyrogenic, lyophilized powder. Each vial contains betiatide (N-[N-[N-[(benzoylthio) acetyl]glycyl]glycyl]-glycine).

Mechanism of Action

CLINICAL PHARMACOLOGY Following intravenous injection of technetium Tc 99m mertiatide, the appearance, concentration, and excretion of the tracer in the kidney can be monitored to assess renal function. Although technetium Tc 99m mertiatide is highly plasma protein bound following intravenous injection, the protein binding is reversible and the tracer is rapidly excreted by the kidneys via active tubular secretion and glomerular filtration. Following intravenous injection of technetium Tc 99m mertiatide in normal volunteers, 89% of the tracer was plasma protein bound. In healthy subjects with normal renal function (mean serum creatinine 1.2 mg/dL) technetium Tc 99m mertiatide was rapidly cleared from the blood. The plasma clearance was approximately 0.

Indications

  • INDICATIONS AND USAGE Technetium Tc 99m mertiatide is a renal imaging agent for use in the diagnosis of congenital and acquired abnormalities, renal failure, urinary tract obstruction, and calculi in adults and pediatric patients. (See Pediatric Use .) It is a diagnostic aid in providing renal function, split function, renal angiograms, and renogram curves for whole kidney and renal cortex.

Common Doses

  • Refer to label

Dosage

DOSAGE AND ADMINISTRATION The suggested dose range employed in the average adult patient (70kg) for renal function and imaging studies is 185 MBq (5 mCi) to 370 MBq (10 mCi). In pediatric patients the recommended dose range is 2.6 MBq/kg (70 μCi/kg) to 5.2 MBq/kg (140 μCi/kg) with a minimum dose of 37 MBq (1 mCi). The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration.

Contraindications

  • CONTRAINDICATIONS None known.

Side Effects

  • ADVERSE REACTIONS The following adverse reactions have been reported: nausea, vomiting, wheezing, dyspnea, itching, rash, tachycardia, hypertension, shaking chills, fever, and seizure.

Interactions

  • No major interactions listed on the FDA label. Always consult a healthcare professional.